Features
- Ideal instrument for testing diesel engine exhaust emissions
- Management of underground diesel equipment in mining applications
- Compatible with testo EasyEmission software
- Measuring range extension for unrestricted measurement at high gas concentrations
- Flue gas analysis with up to 4 gas sensors – freely configurable
- Large selection of probes
- Bluetooth interface
- Convenient measurement data management
Specifications
O2 measurement |
- Measuring range: 0 to 25 Vol. % - Accuracy: ±0.2 Vol. % - Resolution: 0.01 Vol. % - Adjustment time t90: < 20 sec |
---|---|
CO measurement (H2 compensated) |
- Measuring range: 0 to 10,000 ppm - Accuracy: - Resolution: 1 ppm - Adjustment time t90: < 40 sec |
COlow measurement (H2 compensated) |
- Measuring range: 0 to 500 ppm - Accuracy: - Resolution: 0.1 ppm - Adjustment time t90: < 40 sec |
NO measurement |
- Measuring range: 0 to 3,000 ppm - Accuracy: - Resolution: 1 ppm - Adjustment time t90: < 30 sec |
NOlow measurement |
- Measuring range: 0 to 300 ppm - Accuracy: - Resolution: 0.1 ppm - Adjustment time t90: < 30 sec |
NO2 measurement |
- Measuring range: 0 to 500 ppm - Accuracy: - Resolution: 0.1 ppm - Adjustment time t90: < 40 sec |
SO2 measurement |
- Measuring range: 0 to 5,000 ppm - Accuracy: - Resolution: 1 ppm - Adjustment time t90: < 40 sec |
CO2 measurement (Calculated from O2) |
- Measuring range: 0 to CO2 max. - Accuracy: ±0.2 Vol. % - Resolution: 0.1 Vol. % - Adjustment time t90: < 40 sec |
Temperature measurement |
- Measuring range: -40 to +1,200 °C - Accuracy: - Resolution: 0.1 °C |
Draught measurement |
- Measuring range: -40 to +40 hPa - Accuracy: - Resolution: 0.01 hPa |
Differential pressure measurement |
- Measuring range: -200 to 200 hPa - Accuracy: - Resolution: 0.1 hPa |
Absolute pressure measurement |
- Measuring range: 600 to +1.150 hPa - Accuracy: ±10 hPa - Resolution: 1 hPa |