Sales & Support 1300 436 267
Honeywell BW Rig Rat Area Gas Monitoring

BW RigRat

Honeywell BW™ RigRat brings a new level of user-friendliness to transportable multi-gas area monitoring, so your people can work with confidence in hazardous areas. Simply place the monitor nearby, and it will alert workers to area gas threats so they can take action.

Complements your personal gas detectors, protecting workers wherever they’re at risk. Unlike some transportable area monitors, Honeywell BW RigRat is fully self-contained — with no need to repurpose your personal gas detectors for an area monitoring application. Instead, continue using your personal detectors to monitor workers’ breathing zone, while using Honeywell BW RigRat to monitor an area.

Up to six gas sensors — with the flexibility to switch them out as your needs change. Choose from more than 15 4R+ sensors for toxic gases, oxygen, and combustible gases at the lower explosive limit (LEL).

Contact Us for stock levels and order fulfillment

Sales & Support: 1300 436 267
Email: [email protected]

Sensor Range

Features

  • Up to 8 weeks of run time on a single charge
  • Up to six slots for interchangeable gas sensors
  • Integrated noise sensor and meteorological data sensors
  • Highly configurable with programmable input and output
  • Approval for explosive atmosphere
  • Flexible applications
  • One-button operation
  • Simple setup with a smartphone
  • Added protection
  • Wireless safety perimeter
  • Remote monitoring
  • Honeywell TouchPoint Plus compatible
  • Line power for extended run time in the field
  • I/O ports providing additional input capabilities and local executive activation
  • Inert mode that prevents alarm in normal ambient air
  • Large, easy to read display
  • Rugged, weatherproof design, with optional protective cage

Specifications

Technical Specifications

Size

15.8 x 11.4 x 18.5 in. / 40.0 x 29.0 x 47.0 cm

Weight

8 kg/ 17.6 lb

Gas Sensor Slots

Up to 6

Gas Sampling Method

Pumped or diffusion

Battery

Rechargeable Li-ion battery (3.7V/ 26.4 Ah)

Charging Time

Less than 18 hours when the instrument is powered off

Running Time

8 weeks for low-powered model; other models vary by configuration

Keypads

One-button operation and programming

Display

3.5" 240 x 320 TFT color LCD with white LED backlight

Alarm

Red/yellow/ green LED alarm; buzzer alarm 108 dBA @1 m; on-screen indication of alarm conditions

Datalogging

Complete gas sensors and instrument information for at least 4 months at one-minute intervals

Wireless

ISM license free band:

- Bluetooth Low Energy Module (BT 4.2/5.0), 2.4 GHz in default;

- Mesh Module: IEEE 802.15.4 868 MHz / 915MHz /2.4 GHz (optional);

- Wi-Fi Module: 802.11 b/g/n 2.4 GHz (optional)

Radio Module & Range

- Bluetooth Low Energy: RMBLEC, up to 16.4 ft. / 5 m

- Mesh: RM900A or RM2400, up to 984 ft. / 300 m

- Wi-Fi: RMWIFIC, up to 164 ft. / 50 m

Outdoor Location

GPS receiver module: GPS L1 frequency (1575.42 MHz) (optional)

IP Rating

IP65 for pumped models; IP67 for diffusion models

Temperature

-4 to +140° F / -20 to +60° C for pumped models;

-40 to +140° F / -40 to +60° C for diffusion models

Humidity

5 - 95% RH (non‑condensing)

Safety Certifications (Pending)

cCSAus Class I Division 1; Group A, B, C, D; T4;

IEC EX/ATEX

I M1 Ex ia I Ma

II 1G Ex ia da IIC T4 Ga

For LELIR/CO2 sensor installed:

I M1 Ex ia I Ma

II 2G Ex ia da db IIC T4 Gb

1G Ex ia da IIC T4 Ga

Wireless Approvals (Pending)

FCC Part 15, IC, RE-D

ROHS (Pending)

RoHS Compliant, Directive (EU) 2015/863

Noise Sensor

70-110 dBA range; (respond: 100 Hz to 8 kHz), 1 dB resolution;

A-weighted 15 second equivalent level; updated every 5 seconds

External Ports

Safe Area Charge Port (AC CHG Safe Area)

Battery charger input 6 VDC 3A typical; connect to AC/DC adaptor

Feild Charge (IS CHG Hazardous)

Intrinsically safe line power supply input to extend instrument run time (low power model only)

Raemet Port (Serial)

Port to RAEMet wind sensor (optional)

Analog/Switch Input Port (4-20 mA In)

4-20 mA signal input, X1 channel/switch on/off signal input, X1 channel (optional)

On/Off Switch Output (Switch)

Max 20 V/ 120 mA, SPDT Normal Open, X3 channels for external ports (optional). Refer to the User Guide for complete details.

Sensor Specs

Sensor Specifications

Gas Standard Measuring Range Resolution Temperature Range
Combustible Gases (IR) 0-100% LEL/ 0-100% vol. 1% LEL/ 0.1% vol. -40 to +60° C
Combustible Gases (LEL) 0-100% LEL 1% LEL -40 to +60° C
Carbon Dioxide (CO2) 0-5% vol. / 100 ppm 0.01% vol./ 100 ppm -20 to +50° C
Carbon Dioxide (CO2) (Ext. Range) 0-100% vol. 0.1% vol. -20 to +50° C
Volatile Organic Compunds (VOC) 0-2000 ppm 0.1 ppm -20 to +50° C
Carbon Monoxide (CO) 0-500 ppm 1 ppm -40 to +60° C
Carbon Monoxide (CO) (Ext. Range) 0-2000 ppm 10 ppm -20 to +50° C
Carbon Monoxide (CO) (H2 Resistant) 0-1000 ppm 5 ppm -20 to +60° C
Hydrogen Sulfide (H2S) 0-100 ppm 0.1 ppm -40 to +60° C
Hydrogen Sulfide (H2S) (Ext. Range) 0-1000 ppm 1 ppm -20 to +50° C
Sulfur Dioxide (SO2) 0-20 ppm 0.1 ppm -40 to +60° C
Oxygen (O2) 0-30% vol. 0.1% vol. -40 to +60° C
Nitric Oxide (NO) 0-250 ppm 0.5 ppm -20 to +50° C
Nitrogen Dioxide (NO2) 0-20 ppm 0.1 ppm -20 to +50° C
Hydrogen Cyanide (HCN) 0-50 ppm 0.5 ppm -20 to +50° C
Ammonia (NH3) 0-100 ppm 1 ppm -20 to +50° C
Chlorine (CL2) 0-50 ppm 0.1 ppm -20 to +50° C

Video Demo

How to turn on and off you BW RigRat?

Device Set Up

Enquire about BW RigRat