Features
- Guaranteed run time for at least a 12-hour shift — down to -20°C — without compromising LEL detection of hydrogen, acetylene and other combustible gases
- Durable, rechargeable lithium polymer battery — tested to last in extreme environments
- Ergonomic and wearable — doesn’t weigh you down
- Real-time gas concentrations shown onLCD
- Bright, wide-angle visual alarm bars
- IP68 rating ensures maximum protection against dust and water —up to 45 minutes at a depth of 1.2m
- User-friendly, tamperproof operation with just one button and intuitive LCD icons
- IntelliFlash light indicating detector has been bump tested and is monitoring correctly
- Self-test of sensors, battery status, circuit integrity and audible/ visual alarms on startup
- Compatible with IntelliDoX docking station for automated bump tests and calibration
- Multi-language support in English, French, German, Spanish and Portuguese
- Device Management with Honeywell SafetySuite
- Compatible with Honeywell BW Connect for real time monitoring
Specifications
MicroClip XL Specifications
Size |
11.3 x 6.0 x 3.2 cm / 4.4 x 2.4 x 1.2 in. |
---|---|
Weight |
190 g / 6.7 oz. |
Temperature |
-20 to +50°C / -4 to +122°F |
Humidity |
0% - 95% RH (non-condensing) |
Alarms |
Visual, vibrating, audible (95 dB) • Low, High, TWA, STEL, OL (over limit) |
Tests |
Audible/visual alarms on activation; sensors, battery and circuitry (continuous) |
Typical Battery Life |
18 hours; recharges in less than 6 hours Note: Approximately 20% capacity loss is normal with lithium polymer batteries after 500 charge cycles. Refer to the Operator’s Manual for additional information. |
User Options |
• Confidence beep • Set STEL interval • Sensor on/off • Latching alarms • Safe display mode • Stealth mode • Calibration lock • Auto zero on start up • O2 auto calibration on start up • Set bump test interval • Force bump test when overdue |
Ratings |
IP68 – up to 45 minutes at 1.2 m (Honeywell BWTM MicroClip XL and X3) EMI/RFI: Complies with EMC Directive 2004/108/EC |
Certifications and Approvals |
For all certifications, please review the manual or consult Encore Monitoring. |
Warranty |
Full two-year (Honeywell BWTM MicroClip XL) or three-year (Honeywell BWTM MicroClip X3) warranty including all sensors Note: Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of 4°F / -20°C to 122°F / 50°C. |
MicroClip X3 Specifications
Size |
11.3 x 6.0 x 3.2 cm / 4.4 x 2.4 x 1.2 in. |
---|---|
Weight |
179 g / 6.3 oz. |
Temperature |
-20 to +50°C / -4 to +122°F |
Humidity |
0% - 95% RH (non-condensing) |
Alarms |
Visual, vibrating, audible (95 dB) • Low, High, TWA, STEL, OL (over limit) |
Tests |
Audible/visual alarms on activation; sensors, battery and circuitry (continuous) |
Typical Battery Life |
18 hours; recharges in less than 6 hours Note: Approximately 20% capacity loss is normal with lithium polymer batteries after 500 charge cycles. Refer to the Operator’s Manual for additional information. |
User Options |
• IntelliFlashTM interval • Combustible gas measurement (%LEL or % by volume methane) • User-settable calibration gas level • Force calibration when overdue • Low alarm acknowledge • Language choices • Set custom start up message |
Ratings |
IP68 – up to 45 minutes at 1.2 m (Honeywell BWTM MicroClip XL and X3) EMI/RFI: Complies with EMC Directive 2004/108/EC |
Certifications and Approvals |
For all certifications, please review the manual or consult Encore Monitoring. |
Warranty |
Full two-year (Honeywell BWTM MicroClip XL) or three-year (Honeywell BWTM MicroClip X3) warranty including all sensors Note: Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of 4°F / -20°C to 122°F / 50°C. |
Expected Service Lifetime |
Five years including all sensors* (Honeywell BWTM MicroClip X3 only) *Note: Sensors do not contain consumable components and will typically reach the expected lifetime if used according to the instructions in the user manual. Please note that poisoned sensors are not covered by warranty. |
Sensor Specs
Sensor Specifications
Gas | Measuring Range | Resolution |
---|---|---|
H2S | 0-100ppm | 1 pmm |
CO | 0-500ppm | 1 ppm |
O2 | 0-30.0% | 0.1% |
LEL | 0-100% LEL. 0-5.0% v/v | 1%. 0.1% |
Accessories
Confined Space Kit
Part Number: MC-CSE-K
Includes manual aspirator kit, IR Connectivity Kit with Fleet Manager II software, sampling probe, 10 ft. / 3 m sampling hose, carrying case, auxiliary filter kit, calibration cap with 1 ft. / 0.3 m hose, and 0.5 LPM regulator. Detector sold separatelyBW Connect
Part Number: BW-CONNECT
Transforms your unit into a wireless deviceMulti-Unit Power Adaptor
Part Number: GA-PA-1-MC5-AU
Simultaneously charges 5 detectorsMulti-Unit Cradle Charger
Part Number: MC2-C01-MC5
Simultaneously charges 5 detectors in the cradleVehicle Power Adapter
Part Number: GA-VPA-1
12-24VDC adapterAuxiliary Filter Kit
Part Number: MC-AF-K1
Protects the internal filter, kit of 5 filtersManual Aspirator Pump Kit
Part Number: MC-AS01
Kit with probe (0.3m) and tubing