Features
- DPM specific 0-800 Nm particle range
- Communication methods including Wifi, cellular, ethernet, 4-20 mA or direct USB connection
- Over 200 industrial protocol options such as Modbus TCP/IP, OPC
- 8 years of onboard data memory
- Remote diagnostics
- IP Rating of 64
- Automatic sample humidity conditioning
- Automatic temperature and pressure compensation
- Instantaneous pressure compensating, eg blast protection
- Automatic zero drift compensation on every sample
- Multiple power supply options such as 110 – 240V AC, 24V DC and others on request
- Battery back up power supply
- Stainless steel enclosure
- Custom options upon request
Specifications
Specifications
Measurement Technique |
Laser-light scattering photometry |
---|---|
Concentration Range |
0 to 2,500μg/m3 |
Measurement Frequency |
Preset to 5 minute intervals between samples. Range from 2 mins to several hours |
Size Fraction |
≤ 800nm |
Particulate Type |
Particulate Mass is calibrated to the response of a reference photometer gravimetrically calibrated to diesel particulate matter (< 800nm) |
Dimensions |
With external filter 660mm (H) x 250 mm (D) x 740mm (W) Without external filter 660mm (H) x 250mm (D) x 675mm (W) |
Mass |
35.7 kg |
Flow Rate |
2.2 litres per minute |
Operating Humidity Range |
0 to 90% relative humidity (non-condensing) |
Operating Temperature Range |
-10°C to 50°C, 14°F to 122°F |
Enclosure Material |
Stainless Steel (316 grade) |
IP Rating |
IP64 |
Power Option |
240 VAC, 120W Other options available on request |
Protection |
Input surge voltage (1 sec) 50 VDC Overvoltage, overload, short circuit and thermal protection Input: T3.15A/250VAC fused in line and neutral Isolation – Input to Output 4000 VAC, Input and Output to Ground 1500 VAC |
Data Communication Interface Options |
Ethernet: 10/100Base TX (Cat5 RJ45) Wireless: LTE/UMTS (HSPDA/HSPDA+), WiFi (IEEE 802.11b,g,n) Modbus: Modbus TCP Protocol |