Sales & Support 1300 436 267
Pinssar DPM New

Pinssar DPM

Pinssar DPM allows operations to protect workers from dangerous diesel exposure through management and controls. When placed in tunnels, underground mines, diesel engine workshops and confined spaces, the Pinssar DPM monitors diesel exhaust in real time to make sure operations aren’t exceeding occupational exposure limits. Continuous monitoring and correct ventilation ensures greater health and safety.

The Pinssar DPR solution was specifically developed to detect particles smaller than 0.8 micron, or 800 nanometres (nm). With patented diesel emission technology and 23 unique innovations recognised globally. It provides DPM data on a continuous, 24/7 basis to work in conjunction with current mitigation strategies.
The real time data collected by the Pinssar DPR units can be analysed either via the Pinssar Dashboard or by connecting to your company’s preferred Dashboard and/or SCADA package.

Contact Us for stock levels and order fulfillment

Sales & Support: 1300 436 267
Email: [email protected]

  • Features
  • Specifications
  • PDF Download

Features

  • DPM specific 0-800 Nm particle range
  • Communication methods including Wifi, cellular, ethernet, 4-20 mA or direct USB connection
  • Over 200 industrial protocol options such as Modbus TCP/IP, OPC
  • 8 years of onboard data memory
  • Remote diagnostics
  • IP Rating of 64
  • Automatic sample humidity conditioning
  • Automatic temperature and pressure compensation
  • Instantaneous pressure compensating, eg blast protection
  • Automatic zero drift compensation on every sample
  • Multiple power supply options such as 110 – 240V AC, 24V DC and others on request
  • Battery back up power supply
  • Stainless steel enclosure
  • Custom options upon request

Specifications

Specifications

Measurement Technique

Laser-light scattering photometry

Concentration Range

0 to 2,500μg/m3

Measurement Frequency

Preset to 5 minute intervals between samples. Range from 2 mins to several hours

Size Fraction

≤ 800nm

Particulate Type

Particulate Mass is calibrated to the response of a reference photometer gravimetrically calibrated to diesel particulate matter (< 800nm)

Dimensions

With external filter 660mm (H) x 250 mm (D) x 740mm (W)

Without external filter 660mm (H) x 250mm (D) x 675mm (W)

Mass

35.7 kg

Flow Rate

2.2 litres per minute

Operating Humidity Range

0 to 90% relative humidity (non-condensing)

Operating Temperature Range

-10°C to 50°C, 14°F to 122°F

Enclosure Material

Stainless Steel (316 grade)

IP Rating

IP64

Power Option

240 VAC, 120W Other options available on request

Protection

Input surge voltage (1 sec) 50 VDC

Overvoltage, overload, short circuit and thermal protection

Input: T3.15A/250VAC fused in line and neutral

Isolation – Input to Output 4000 VAC, Input and Output to Ground 1500 VAC

Data Communication Interface Options

Ethernet: 10/100Base TX (Cat5 RJ45)

Wireless: LTE/UMTS (HSPDA/HSPDA+), WiFi (IEEE 802.11b,g,n)

Modbus: Modbus TCP Protocol